Media 000170158: Mdicect
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000170158
Media type
Volumetric Image Series
Object element or part
mdicect
Object represented
Object taxonomy
Desmodus rotundus
Side
--
Orientation
--
Short description
zipped tiff stack
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives
Creator
--
Date created
--
Date uploaded
December 22, 2020

FILE OBJECT DETAILS Field Definitions

File name
ummz-mammals-112690_Desmodus-rotundus_MdiceCT.zip
File format(s)
ZIP archive, TIFF
File size
3.71 GB
Image width
1380
Image height
905
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.041556
Y pixel spacing
0.041556
Z pixel spacing
0.041556
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,000

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
University of Michigan Museum of Zoology (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701713; oVert TCN; NSF DBI-1701714
Publisher
University of Michigan, Museum of Zoology, 3600 Varsity Drive, Ann Arbor, Michigan 48108
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of Michigan Museum of Zoology provided access to these data , the collection of which was funded by oVert TCN. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UMMZ:mammals:112960 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
University of Michigan Museum of Zoology, Research Museums Center (University of Michigan)
Creator
Ramon Nagesan, Shion Otsuka
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
unknown
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
unknown
Projections
3141
Voltage
85
Power
0.017
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000170158: Mdicect [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Ramon Nagesan, Shion Otsuka
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000170158: Mdicect [CTImageSeries] [CT] (this media)