Media 000170444: Element Unspecified [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000170444
Media type
CTImageSeries
Object element or part
--
Side
--
Orientation
--
Short description
zipped dicom
Full description
Migrated MorphoSource 1 Media File Title: zipped dicom Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Migrated MorphoSource 1 Media Group Description: Fluid-preserved
Creator
--
Date created
--
Date uploaded
January 01, 2021

FILE OBJECT DETAILS

File format(s)
application/dicom
File size
4.27 GB
Image width
1236
Image height
1605
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.068051
Y pixel spacing
0.068051
Z pixel spacing
0.068051
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,825

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
Field Museum's Grainger Bioinformatics and Bass Postdoctoral Fellowships (C.M.E.)
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: American Museum of Natural History provided access to these dataoriginally appearing in Eliason et al. (2021) , with data collection funded by the Field Museum's Grainger Bioinformatics and Bass Postdoctoral Fellowships (C.M.E.). The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:birds:10535 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Neander
Date
April 12, 2021
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
190
Power
0.0361
Amperage
190
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000170444: Element Unspecified [CTImageSeries] [CT] (this media).

Processing Details

Creator
April Neander
Date processed
April 12, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000170444: Element Unspecified [CTImageSeries] [CT] (this media)