Media 000170728: Ankle
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Team
· Public
Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000170728
Media type
Volumetric Image Series
Object element or part
ankle
Object represented
Object taxonomy
Hipposideros commersoni
Object organization
Side
--
Orientation
--
Short description
HRXCT scan - ankle
Full description
University of Texas High-Resolution X-ray CT Facility Archive 0862 Simmons: Hipposideros: Scans of the ankle of Hipposideros commersoni (AMNH 268379; no locality info) for Dr. Nancy Simmons of the American Museum of Natural History and Dr. Timothy Rowe of the Department of Geological Sciences, The University of Texas at Austin. Scanned by Matthew Colbert 6 May 2003. ankle/16bitrf: 512x512 16-bit TIFF images. II, 120 kV, 0.2 mA, no filter, empty wedge, no offset, slice thickness 1 line (= 0.021 mm), S.O.D. 60 mm, 1000 views, 3 samples per view, inter-slice spacing 1 line (= 0.021 mm), field of reconstruction 10 mm (maximum field of view 19.66222 mm), reconstruction offset 6500, reconstruction scale 1650. Reconstructed off-center: x = 2, y = -0.2. Acquired with 27 slices per rotation. Flash- and ring-removal processing done by Rachel Racicot based on correction of raw sinogram data using IDL routines “RK_SinoDeSpike” and “RK_SinoRingProcSimul”, both with default parameters. Deleted original slice 27. Total slices = 296.
Creator
--
Date created
May 05, 2003
Date uploaded
January 08, 2021

FILE OBJECT DETAILS Field Definitions

File name
File format(s)
ZIP archive, TIFF
File size
98.4 MB
Image width
484
Image height
438
Color space
BlackIsZero
Color depth
16
Compression
--
X pixel spacing
0.020000
Y pixel spacing
0.020000
Z pixel spacing
0.021000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
296

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
AMNH Dept of Mammalogy
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Permitted
Required archival of published derivatives
On MorphoSource
Funding attribution
DEB-9873663, DBI-1902242
Publisher
oUTCT PEN
Cite as
Nancy Simmons provided access to these data, with data collection funded by NSF DEB-9873663 and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Mammals:M-268379 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
May 06, 2003
Software
--
Description
--
Description Attachment
None
Photographic Reference
None
Filter
--
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1000
Voltage
120
Power
--
Amperage
200
Surrounding material
empty container
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000170728: Ankle [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Matthew Colbert
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000170728: Ankle [CTImageSeries] [CT] (this media)