Media 000344884: Calcaneus [Mesh] [CT]
Represents:
Biological Specimen
In Collection

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000344884
Media type
Mesh
File format(s)
application/ply
File size
20,564,177 bytes
Object element or part
Calcaneus
Side
Right
Orientation
--
Short description
Smooth surface file
Full description
--
Creator
--
Date created
--
Date uploaded
February 15, 2021
Points
276,830
Polygons
553,644
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.271, 9.631, 12.521
Centroid coordinates
9.785, 4.993, 7.493
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Open Download
Download reviewer
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
--
Funding attribution
--
Publisher
--
Cite as
--
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:919m was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich
Date
2021-02-14
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
1
Projections
1800
Voltage
155
Power
0.018
Amperage
120
Surrounding material
air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000015692: Foot [CTImageSeries] [CT] .

Processing Details

Creator
Gabriel Yapuncich
Date processed
2021-02-14
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000015692: Foot [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000344884: Calcaneus [Mesh] [CT] (this media).

Processing Details

Creator
Gabriel Yapuncich
Date processed
2021-02-15
Software
Avizo 2019.3
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo 2019.3
Description

Media produced by this event on MorphoSource


Media 000344884: Calcaneus [Mesh] [CT] (this media)