Media 000345065: Upper Right Canine [Mesh] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000345065
Media type
Mesh
File format(s)
application/ply
File size
1,003,742 bytes
Object element or part
Upper Right Canine
Side
Right
Orientation
Upper
Short description
Tooth
Full description
Upper right canine of Phacochoerus aethiopicus.
Creator
--
Date created
--
Date uploaded
February 17, 2021
Points
30,404
Polygons
49,130
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
146.219, 32.467, 41.434
Centroid coordinates
22.36, -2.928, -1.241
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Philips Brilliance 180Pz, Donald Gordon Medical Centre (University of the Witwatersrand)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Australian Research Council; Monash University
Publisher
Monash University
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dnmnh:35497 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Philips Brilliance 180Pz
Device facility
Donald Gordon Medical Centre (University of the Witwatersrand)
Creator
Adams, Justin
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000345065: Upper Right Canine [Mesh] [CT] (this media).

Processing Details

Creator
Evans, Alistair
Date processed
2021-02-16
Software
Avizo
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000345065: Upper Right Canine [Mesh] [CT] (this media)