Media 000346019: Forelimbs
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000346019
Media type
Volumetric Image Series
Object element or part
Forelimbs
Object represented
Object taxonomy
Necturus maculatus
Object organization
Side
--
Orientation
--
Short description
AMNH_FS-26617
Full description
DiceCT of forelimbs of Necturus maculatus
Creator
--
Date created
--
Date uploaded
February 22, 2021

FILE OBJECT DETAILS Field Definitions

File name
Necturus_stn_JM_22Dec2020_FL_HiRes_Rec.zip
File format(s)
ZIP archive, TIFF
File size
2.19 GB
Image width
2240
Image height
448
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
32.500000
Y pixel spacing
32.500000
Z pixel spacing
32.500000
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,904

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, New York Institute of Technology Visualization Center (New York Institute of Technology)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
Molnar, JL. (2021). Variation in articular cartilage thickness among extant salamanders and implications for the tetrapod water-land transition. Frontiers in Ecology and Evolution.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:herpetology:FS-26617 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
New York Institute of Technology Visualization Center (New York Institute of Technology)
Creator
Molnar, Julia
Event date
December 22, 2020
Software
SkyScan1173 version 1.6
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000346019: Forelimbs [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Molnar, Julia
Event date
December 22, 2020
Software
NRecon
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000346019: Forelimbs [CTImageSeries] [CT] (this media)