Media 000346405: Pes
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000346405
Media type
Volumetric Image Series
Object element or part
Pes
Object represented
Object taxonomy
Eublepharis macularius
Side
NotApplicable
Orientation
--
Short description
DICECT Zstack of pes
Full description
--
Creator
--
Date created
--
Date uploaded
February 25, 2021

FILE OBJECT DETAILS Field Definitions

File name
UF-H-78934-pes.zip
File format(s)
ZIP archive, TIFF
File size
312 MB
Image width
1011
Image height
471
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.019999
Y pixel spacing
0.019999
Z pixel spacing
0.019999
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,574

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Open Download
IP holder
Florida Museum of Natural History, University of Florida
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:78934 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
February 23, 2021
Software
Phonix Datos X
Description
DICECT scan of UF-H-78934 pes
Description attachment
None
Reference attachment
None
Exposure time
0.200098
Flux normalization
Yes
Pixel spacing calibration
Geometry
Shading correction
Yes
Frame averaging
3
Projections
1800
Voltage
125
Power
31.250
Amperage
250
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
2014
Detector pixels size X
--
Detector pixels Y
2024
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
Tungston
Rotation number
1800
Phase contrast
No
Optical magnification
Yes
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000346405: Pes [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
February 23, 2021
Software
DatosX R
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
DatosX R
Description

Media produced by this event on MorphoSource

Media 000346405: Pes [CTImageSeries] [CT] (this media)