Media 000347062: Element Unspecified
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000347062
Media type
Volumetric Image Series
Object element or part
--
Object represented
Object taxonomy
Furcifer angeli
Side
--
Orientation
--
Short description
Furcifer angeli
Full description
Furcifer angeli specimen indicated by radiopaque "hollow K" marker
Creator
--
Date created
--
Date uploaded
March 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
Furcifer_angeli_ZFMK_59781_ChameleonTube32.zip
File format(s)
ZIP archive, BMP
File size
12.6 GB
Image width
1644
Image height
2494
Color space
--
Color depth
8
Compression
0; BI_RGB; None
Series type
Reconstructed image stack
X pixel spacing
0.025200
Y pixel spacing
0.025200
Z pixel spacing
0.025200
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
5,884

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
--
IP holder
Christopher V. Anderson (Copyright and License)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
The collection of this scan was funded by the University of South Dakota; NSF DBI-1701665
Publisher
--
Cite as
Christopher V. Anderson provided access to these data originally appearing in MorphoSource, the collection of which was funded by University of South Dakota. The files were downloaded from www.MorphoSource.org, Duke University
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object zfmk:59781 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Anderson, Christopher V.
Event date
March 25, 2021
Software
--
Description
Specimen identified by radiopaque "hollow K" marker
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000347062: Element Unspecified [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Anderson, Christopher V.
Event date
March 02, 2021
Software
--
Description
Specimen identified by radiopaque "hollow K" marker
Description attachment
None

Media produced by this event on MorphoSource