Media 000347487: Element Unspecified [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000347487
Media type
CTImageSeries
Object element or part
--
Side
--
Orientation
--
Short description
Trioceros balebicornutus
Full description
Trioceros balebicornutus specimen indicated by radiopaque "hollow V" marker
Creator
--
Date created
--
Date uploaded
March 04, 2021

FILE OBJECT DETAILS

File format(s)
image/bmp
File size
710 MB
Image width
836
Image height
746
Color space
--
Color depth
8
Compression
0
Series type
Reconstructed image stack
X pixel spacing
0.026600
Y pixel spacing
0.026600
Z pixel spacing
0.026600
Pixel spacing units
Mm
Number of images in set
2,248

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Christopher V. Anderson (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
The collection of this scan was funded by the University of South Dakota; NSF DBI-1701665
Publisher
--
Cite as
Christopher V. Anderson provided access to these data originally appearing in MorphoSource, the collection of which was funded by University of South Dakota. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object zfmk:84816 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
Anderson, Christopher V.
Date
March 25, 2021
Software
--
Description
Specimen identified by radiopaque "hollow V" marker
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000347487: Element Unspecified [CTImageSeries] [CT] (this media).

Processing Details

Creator
Anderson, Christopher V.
Date processed
March 04, 2021
Software
--
Description
Specimen identified by radiopaque "hollow V" marker
Description attachment
None

Media produced by this event on MorphoSource


Media 000347487: Element Unspecified [CTImageSeries] [CT] (this media)