Media 000349205: Mandible
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000349205: Mandible
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000349205
Media type
Mesh
Object element or part
Mandible
Object represented
Object taxonomy
Homo sapiens
Object organization
Side
Left
Orientation
--
Short description
Mandible PLY hi-res
Full description
High resolution PLY model with internal structures and ambient occlusion shading. Embedded tooth was segmented and shaded differently and can be separated in Meshlab.
Creator
Simmons-Ehrhardt, Terrie
Date created
--
Date uploaded
March 12, 2021
FILE OBJECT DETAILS Field Definitions
File name
NMHM2007_2001_05_hires.ply
File format(s)
PLY
File size
225 MB
Points
5596092
Polygons
11264620
Map type
--
UV coordinates
False
Vertex color
True
Bounding box dimensions
44.323, 100.163, 60.315
Centroid coordinates
-22.897, -41.338, 23.722
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000, Federal Bureau of Investigation (Federal Bureau of Investigation)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
National Museum of Health and Medicine
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
nmhm:path:NMHM-2007.2001.05
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging X5000
Device facility
Federal Bureau of Investigation (Federal Bureau of Investigation)
Creator
--
Event date
June 26, 2018
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
28m44s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
4
Projections
1000
Voltage
135
Power
--
Amperage
250
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2048
Detector pixels size X
0.2
Detector pixels Y
2048
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
353.954
Source detector distance
1025.225
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 1 activity
to create
derived
Media 000349205: Mandible [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Simmons-Ehrhardt, Terrie
Event date
March 12, 2021
Software
3D Slicer
Description
16bit DICOMs were imported into 3D Slicer, converted to 8-bit and resampled to 0.133346 mm voxels. Bone was segmented with Segment Editor. Cleaning and shading was applied in Meshlab.
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
3D Slicer
Description
Media produced by this event on MorphoSource
Media 000349205: Mandible [Mesh] [CT] (this media)