Media 000350208: Whole Body [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000350208
Media type
Mesh
File format(s)
application/ply
File size
47.2 MB
Object element or part
Whole body
Side
--
Orientation
--
Short description
Whole body, CT scan image of Pedioplanis branchi sp. nov. paratype
Full description
Whole body, CT scan image of Pedioplanis branchi sp. nov. paratype
Creator
Bauer, Aaron; Childers, Jackie; Kirchhof, Sebastian
Date created
--
Date uploaded
March 17, 2021
Points
1,574,987
Polygons
2,349,211
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
82.064, 42.519, 27.124
Centroid coordinates
1.245, 1.091, 0.071
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Phoenix Nanotom, Museum für Naturkunde, Berlin (Museum für Naturkunde, Berlin)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
German Academic Exchange Service (DAAD) and the Elsa-Neumann-Stipendium
Publisher
Museum für Naturkunde, Berlin
Cite as
J. L. Childers, S. Kirchhof, and A. M. Bauer provided access to these data originally appearing in Childers et al., 2021, the generation of which was funded by NSF grant EF1241885, subaward 13–0632 to Aaron M. Bauer, and by the German Academic Exchange Service (DAAD) and Elsa-Neumann-Stipendium des Landes Berlin (Humboldt University of Berlin, Germany) to Sebastian Kirchhof. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
doi: 10.7479/4jg6-ae46
External media URL
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
zmb:h:ZMB 89310
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric Phoenix Nanotom
Device facility
Museum für Naturkunde, Berlin (Museum für Naturkunde, Berlin)
Creator
Kristin Mahlow
Date
2021-03-17
Software
VG Studio Max 3.1
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
60 s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1440 projections
Voltage
85 kV
Power
--
Amperage
120 or 150
Surrounding material
--
Xray tube type
Phoenix nanotom
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000350208: Whole Body [Mesh] [CT]
(this media).
Processing Details
Creator
Kristin Mahlow
Date processed
2021-03-17
Software
VG Studio Max 3.1
Description
--
Description attachment
None
Media produced by this event on MorphoSource

Media 000350208: Whole Body [Mesh] [CT] (this media)