Media 000350272: Element Unspecified [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
FILE OBJECT DETAILS
Media ID
000350272
Media type
CTImageSeries
File format(s)
image/bmp
File size
6.48 GB
Object element or part
--
Side
--
Orientation
--
Short description
Trioceros oweni
Full description
Trioceros oweni specimen indicated by radiopaque "C" marker
Creator
--
Date created
--
Date uploaded
March 17, 2021
Image width
1584
Image height
2036
Color space
--
Color depth
8
Compression
BI_RGB
Series type
Reconstructed image stack
X pixel spacing
0.034600
Y pixel spacing
0.034600
Z pixel spacing
0.034600
Pixel spacing units
Mm
Number of images in set
4,045
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173, Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Museum of Comparative Zoology, Harvard University; © President and Fellows of Harvard College (Copyright and License)
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
The collection of this scan was funded by the University of South Dakota; NSF DBI-1701665
Publisher
--
Cite as
Christopher V. Anderson provided access to these data originally appearing in MorphoSource, the collection of which was funded by University of South Dakota. The files were downloaded from www.MorphoSource.org, Duke University. Specimen courtesy of Museum of Comparative Zoology, Harvard University, © President and Fellows of Harvard College
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
mcz:herp:r-7829
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 1173
Device facility
Karel F. Liem Bioimaging Facility of Friday Harbor Labs (University of Washington)
Creator
--
Date
2021-03-30
Software
--
Description
Specimen identified by radiopaque "C" marker
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
65
Power
--
Amperage
123
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000350272: Element Unspecified [CTImageSeries] [CT]
(this media).
Processing Details
Creator
Anderson, Christopher V.
Date processed
2021-03-17
Software
--
Description
Specimen identified by radiopaque "C" marker
Description attachment
None
Media produced by this event on MorphoSource

Media 000350272: Element Unspecified [CTImageSeries] [CT] (this media)