Media 000351282: Head [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000351282
Media type
CTImageSeries
File format(s)
image/tiff
File size
5,397,452,394 bytes
Object element or part
head
Side
--
Orientation
--
Short description
--
Full description
University of Texas High-Resolution X-ray CT Facility Archive Torres: L_noctis510969: Scan of the head of Loxigilla noctis (USNM 510969; St. Lucia) for Chris Torres of The University of Texas at Austin. Specimen scanned by Matthew Colbert on 3 May 2016. 16bitTIFF: Scan parameters: NSI scanner. Fein Focus High Power source, 150 kV, 0.1 mA, no filter, Perkin Elmer detector, 0.25 pF gain, 1 fps, 1x1 binning, no flip, source to object 154.0 mm, source to detector 1316.772 mm, continuous CT scan, no frames averaged, 0 skip frames, 2500 projections, 6 gain calibrations, 5 mm calibration phantom, data range [-10.0, 250.0] (grayscales adjusted from NSI defaults), beam-hardening correction = 0.0. Specimen reoriented prior to reconstruction. Voxel size = 14.1 μm. Total slices = 1806.
Creator
--
Date created
--
Date uploaded
March 22, 2021
Image width
1038
Image height
1576
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.0141
Y pixel spacing
0.0141
Z pixel spacing
0.0141
Pixel spacing units
Mm
Slice thickness
0.014
Number of images in set
1,818

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
Name: National Museum of Natural History, Type: Copyright and License
Funding attribution
DBI-1902242
Publisher
oUTCT PEN
Cite as
Chris Torres provided access to these data, with upload to MorphoSource funded by DBI-1902242
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object usnm:birds:510970 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Colbert, Matthew
Date
2016-05-02
Software
--
Description
head
Imaging event description attachment
Imaging event reference attachment
None
Exposure time
1s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
--
Projections
2625
Voltage
150 kV
Power
--
Amperage
0.1 mA
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000351282: Head [CTImageSeries] [CT] (this media).

Processing Details

Creator
--
Date processed
2021-03-22
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000351282: Head [CTImageSeries] [CT] (this media)