Media 000353537: Cranium [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000353537
Media type
CTImageSeries
File format(s)
image/jpeg
File size
171,640,821 bytes
Object element or part
Cranium
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
March 26, 2021
Image width
1951
Image height
1073
Color space
YCbCr
Color depth
8
Compression
JPEG
Series type
Reconstructed image stack
X pixel spacing
0.031
Y pixel spacing
0.031
Z pixel spacing
0.031
Pixel spacing units
Mm
Number of images in set
1,923

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Download reviewer
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
Name: Texas memorial Museum (TMM), Type:
Funding attribution
NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
--
Additial usage agreement
None
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:43670-2 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
2017-04-25
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
2
Projections
3000
Voltage
120 kV
Power
--
Amperage
165 uA
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
228.0 mm
Source detector distance
1319.961 mm
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000353537: Cranium [CTImageSeries] [CT] (this media).

Processing Details

Creator
Maisano, Jessie
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource