Media 000353537: Cranium
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000353537
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Kayentachelys aprix
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
March 26, 2021

FILE OBJECT DETAILS Field Definitions

File name
Kayentachelys_aprix_TMM_43670-2_8bitJPG.zip
File format(s)
ZIP archive, JPEG
File size
164 MB
Image width
1951
Image height
1073
Color space
YCbCr
Color depth
8
Compression
JPEG
Series type
Reconstructed image stack
X pixel spacing
0.031000
Y pixel spacing
0.031000
Z pixel spacing
0.031000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,923

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Texas memorial Museum (TMM)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NERC studentship to SWE on the DTP Environmental Research (NE/L0021612/1)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object tmm:43670-2 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Event date
April 25, 2017
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
2
Projections
3000
Voltage
120 kV
Power
--
Amperage
165 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
228.0 mm
Source detector distance
1319.961 mm
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000353537: Cranium [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Maisano, Jessie
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000353537: Cranium [CTImageSeries] [CT] (this media)