Media 000354067: Head
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000354067
Media type
Volumetric Image Series
Object element or part
Head
Object represented
Object taxonomy
Polemon christyi
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
March 29, 2021

FILE OBJECT DETAILS Field Definitions

File name
RMCA-VERT-R.14373_Melanocalamus_leopoldi_Type_Head.zip
File format(s)
ZIP archive, TIFF
File size
3.96 GB
Image width
1071
Image height
1702
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.016130
Y pixel spacing
0.016130
Z pixel spacing
0.016130
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,303

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
RX Solutions EasyTom 150, Scanning Facilities of RBINS Scientific Survey of Heritage (SSH) (Royal Belgian Institute of Natural Sciences)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
RMCA (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
DIGIT04, BELSPO
Publisher
RMCA
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object rmca:vert:R.14373 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
RX Solutions EasyTom 150
Device facility
Scanning Facilities of RBINS Scientific Survey of Heritage (SSH) (Royal Belgian Institute of Natural Sciences)
Creator
Brecko, Jonathan
Event date
March 30, 2021
Software
Xact
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
110
Power
91
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000354067: Head [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Brecko, Jonathan
Event date
March 29, 2021
Software
Xact
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Media produced by this event on MorphoSource

Media 000354067: Head [CTImageSeries] [CT] (this media)