Media 000354170: Cranium
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000354170
Media type
Volumetric Image Series
Object element or part
Cranium
Object represented
Object taxonomy
Chelydropsis murchisoni
Side
NotApplicable
Orientation
--
Short description
Note that scan wobbled a bit, and anterior part of cranium is affected by this is scan
Full description
--
Creator
--
Date created
--
Date uploaded
March 30, 2021

FILE OBJECT DETAILS Field Definitions

File name
Chelydropsis_murchisoni_BSPG1980I158.zip
File format(s)
ZIP archive, TIFF
File size
911 MB
Image width
1586
Image height
938
Color space
BlackIsZero
Color depth
8
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.042000
Y pixel spacing
0.042000
Z pixel spacing
0.042000
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,293

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 2211, CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
Bayerische Staatssammlung für Paläontologie und Geologies (BSPG)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object snsb-bspg:1980I158 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Bruker SkyScan 2211
Device facility
CT Imaging Lab at the Department of Geosciences of the University of Fribourg (University of Fribourg)
Creator
Joyce, Walter
Event date
February 10, 2020
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
120 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
165 kV
Power
--
Amperage
147 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000354170: Cranium [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Joyce, Walter
Event date
February 10, 2020
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000354170: Cranium [CTImageSeries] [CT] (this media)