Media 000354710: Skeleton
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000354710: Skeleton
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000354710
Media type
Mesh
Object element or part
Skeleton
Object represented
Object taxonomy
Xenopus victorianus
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
April 02, 2021
FILE OBJECT DETAILS Field Definitions
File name
AMNH_A40390.ply
File format(s)
PLY
File size
12.3 MB
Points
304835
Polygons
615211
Map type
Color
UV coordinates
False
Vertex color
True
Bounding box dimensions
30.623, 13.016, 43.190
Centroid coordinates
0.912, 1.630, 1.583
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(2 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
AMNH:Herpetology:A-40390
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.333137
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1200
Voltage
100
Power
0.02
Amperage
200
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000067425: Element Unspecified [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Edward Stanley
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000067425: Element Unspecified [CTImageSeries] [Etc]
was processed
with 2 activities
to create
derived
Media 000354710: Skeleton [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Edward Stanley
Event date
April 02, 2021
Software
VGstudioMax 3.4
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
VGStudioMax 3.4
Description
Processing Activity 2: Mesh and/or Point Cloud Texturing
Software
Meshlab
Description
Media produced by this event on MorphoSource
Media 000354710: Skeleton [Mesh] [CT] (this media)