Media 000354740: Skeleton [Mesh] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

GENERAL DETAILS

Media ID
000354740
Media type
Mesh
Object element or part
Skeleton
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
April 02, 2021

FILE OBJECT DETAILS

File format(s)
application/ply
File size
15.4 MB
Points
382,197
Polygons
773,098
Map type
Color
UV coordinates
False
Vertex color
True
Bounding box dimensions
32.590, 11.678, 39.198
Centroid coordinates
-1.358, 0.571, 2.384
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
President and Fellows of Harvard College (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mcz:herp:a-139853 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.3
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1000
Voltage
90
Power
0.0126
Amperage
140
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000050547: 16 Bit Tiff Stack [CTImageSeries] [Etc] .

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000050547: 16 Bit Tiff Stack [CTImageSeries] [Etc] was processed with 1 activity to create derived Media 000354740: Skeleton [Mesh] [CT] (this media).

Processing Details

Creator
Edward Stanley
Date processed
April 02, 2021
Software
VGstudioMax 3.4
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
VGStudioMax 3.4
Description

Media produced by this event on MorphoSource


Media 000354740: Skeleton [Mesh] [CT] (this media)