Media 000355587: Full Body
Open Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
ยท Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000355587
Media type
Volumetric Image Series
Object element or part
Full body
Object represented
Object taxonomy
Pelusios subniger
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
April 07, 2021

FILE OBJECT DETAILS Field Definitions

File name
Pelusios_subniger_or_castaneus_UMZC_R.18170.zip
File format(s)
ZIP archive, TIFF
File size
694 MB
Image width
641
Image height
1153
Color space
BlackIsZero
Color depth
8
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.079057
Y pixel spacing
0.079057
Z pixel spacing
0.079057
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,999

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
University Museum of Zoology Cambridge (UMZC)
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object umzc:vertebrates:R.18170 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
Benson, Roger
Event date
October 29, 2019
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
1000 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
165 kV
Power
--
Amperage
165 uA
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000355587: Full Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Benson, Roger
Event date
October 29, 2019
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000355587: Full Body [CTImageSeries] [CT] (this media)