Media 000359368: Head Mri Pd
Open Download
Type Volumetric Image Series
Modality Magnetic Resonance Imaging (MRI)
Media represents biological specimen
Managed by

Media Display

In Collections

No collections found.

GENERAL DETAILS Field Definitions

Media ID
000359368
Media type
Volumetric Image Series
Object element or part
head MRI PD
Object represented
Object taxonomy
Homo sapiens
Object organization
Side
--
Orientation
axial
Short description
Data is the head of a 72 year old male donor. The donor was preserved in formalin and the blood vessels were filled with araldite-F. Before freezing, MRI and CAT imaging was preformed.
Full description
Brigham and Women's Hospital Havard Medical School Dr. Peter Ratiu ratiu@bwh.havard.edu Data is the head of a 72 year old male donor. The donor was preserved in formalin and the blood vessels were filled with araldite-F. Before freezing, MRI and CAT imaging was preformed. After freezing the specimen was cryo sectioned at 0.147mm intervals and digital photographs were taken with a resolution of 1056 x 1528 pixels. For a complete description of the procedure see: P. Ratiu, B. Hillen, J. Glase and D.P. Jenkins. 'Visible Human 2.0 - The Next Generation' "Medicine Meets Virtual Reality 11 - NextMed: Health Horizon" edited by J.D. Westwood et al. IOS Press, 2003. pp 275-281. This work was performed under contract LM-1-3535 "The Visible Human Project Anatomical Methods" Please read the following README files for further information: README-CAT.txt README_MRI.txt README_cryo.txt Directory Tree of Data ./MR_CT_DICOM ./MR_CT_DICOM/CAT ./MR_CT_DICOM/MRI ./MR_CT_DICOM/MRI/PD ./MR_CT_DICOM/MRI/T1 ./MR_CT_DICOM/MRI/T2 ./MR_CT_DICOM/MRI/T2_512 ./MR_CT_tiffs ./MR_CT_tiffs/CAT-tiff ./MR_CT_tiffs/MRI-tiff ./MR_CT_tiffs/MRI-tiff/PD-tiff ./MR_CT_tiffs/MRI-tiff/T1-tiff ./MR_CT_tiffs/MRI-tiff/T2-tiff ./MR_CT_tiffs/MRI-tiff/T2_512-tiff ./cryo ./cryo/tiff ./cryo/jpeg ./cryo/jpeg/fullSize ./cryo/jpeg/fullSize/axial ./cryo/jpeg/fullSize/axial/.xvpics ./cryo/jpeg/fullSize/coronal ./cryo/jpeg/fullSize/sagittal ./cryo/jpeg/halfSize ./cryo/jpeg/halfSize/axial ./cryo/jpeg/halfSize/sagittal ./cryo/jpeg/halfSize/coronal ./cryo/jpeg/quarterSize ./cryo/jpeg/quarterSize/axial ./cryo/jpeg/quarterSize/sagittal ./cryo/jpeg/quarterSize/coronal
Creator
--
Date created
--
Date uploaded
April 21, 2021

FILE OBJECT DETAILS Field Definitions

File name
Visible_Human_2_MRI_PD.zip
File format(s)
ZIP archive, DICOM
File size
4.45 MB
Image width
256
Image height
256
Color space
--
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.937500
Y pixel spacing
0.937500
Z pixel spacing
3.000000
Pixel spacing units
Mm
Slice thickness
3.000000
Number of images in set
76

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
Magnetic Resonance Imaging (MRI)
Device
Philips Gyroscan NT, University Medical Center Utrecht (University Medical Center Utrecht)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
National Library of Medicine (Copyright and License)
Copyright statement
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nlm:NLM:2 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
Magnetic Resonance Imaging (MRI)
Device
Philips Gyroscan NT
Device facility
University Medical Center Utrecht (University Medical Center Utrecht)
Creator
--
Event date
April 05, 2002
Software
--
Description
--
Description attachment
None
Reference attachment
None

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000359368: Head Mri Pd [CTImageSeries] [MRI] (this media).

Processing Details Field Definitions

Creator
--
Event date
April 21, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000359368: Head Mri Pd [CTImageSeries] [MRI] (this media)