Media 000359536: Endocast [Mesh] [CT]
Represents:
Biological Specimen
In Collection

GENERAL DETAILS

Media ID
000359536
Media type
Mesh
Object element or part
Endocast
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
April 23, 2021

FILE OBJECT DETAILS

File format(s)
application/ply
File size
119 MB
Points
1,587,209
Polygons
3,180,030
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
25.708, 20.739, 32.745
Centroid coordinates
19.043, 18.137, 15.008
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:baa:0006 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
K.L. Allen
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
--
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
--
Projections
2450
Voltage
142
Power
--
Amperage
203
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000001868: Skull [CTImageSeries] [Etc] .

Processing Details

Creator
K.L. Allen
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000001868: Skull [CTImageSeries] [Etc] was processed to create derived Media 000359536: Endocast [Mesh] [CT] (this media).

Processing Details

Creator
Date processed
April 23, 2021
Software
Avizo
Description
Endocast constructed through segmentation of CT data.
Description attachment
None

Media produced by this event on MorphoSource


Media 000359536: Endocast [Mesh] [CT] (this media)