Media 000362641: Skeleton [Mesh] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000362641
Media type
Mesh
File format(s)
application/stl
File size
179,259,484 bytes
Object element or part
Skeleton
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 06, 2021
Points
1,792,156
Polygons
3,585,042
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
146.71, 73.214, 162.156
Centroid coordinates
-0.854, 5.868, 2.629
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF DBI-1701714 ("oVert: TCN" parent grant)
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object lsumz:herps:88802 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Zachary Randall
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.2
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
3
Projections
1800
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000073953: Whole Body [CTImageSeries] [Etc] .

Processing Details

Creator
Zachary Randall
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000073953: Whole Body [CTImageSeries] [Etc] was processed to create derived Media 000362641: Skeleton [Mesh] [CT] (this media).

Processing Details

Creator
Jaimi Gray
Date processed
2021-05-06
Software
VG Studio Max
Description
Skeleton
Description attachment
None

Media produced by this event on MorphoSource


Media 000362641: Skeleton [Mesh] [CT] (this media)