Media 000362754: Head [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000362754
Media type
CTImageSeries
File format(s)
image/tiff
File size
1,527,629,199 bytes
Object element or part
head
Side
--
Orientation
--
Short description
--
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1081 Cannatella Dermophis: Scans of the head of Dermophis mexicanus (MVZ 179494) for Dr. David Canatella of The University of Texas at Austin. Specimen scanned by Philip Watson 24 September 2004. 16bit: 1024x1024 16-bit TIFF images. II, 180 kV, 0.133 mA, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.0376 mm), S.O.D. 55 mm, 1600 views, 3 samples per view, inter-slice spacing 2 lines (= 0.0376 mm), field of reconstruction 17 mm (maximum field of view 18.00608 mm), reconstruction offset 5200, reconstruction scale 1860. Acquired with 15 slices per rotation. Drift- and ring-correction done by Susan Garlock on raw sinogram data using IDL routines “RK_SinoDeDrift” and “RKSinoRingProcSimul”. Reconstruction done with C-ray correction of -11 and +15 degree rotation. Total slices = 585.
Creator
--
Date created
September 24, 2004
Date uploaded
May 07, 2021
Image width
980
Image height
840
Color space
BlackIsZero
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.0166
Y pixel spacing
0.0166
Z pixel spacing
0.0376
Pixel spacing units
Mm
Slice thickness
0.038
Number of images in set
585

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334952, DBI-1902242
Publisher
oUTCT PEN
Cite as
David Cannatella provided access to these data, with data collection funded by NSF EF-0334952 and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mvz:amphibian and reptile specimens:179494 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Philip Watson
Date
2004-09-24
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
3
Projections
1600
Voltage
180
Power
--
Amperage
133
Surrounding material
empty container
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000362754: Head [CTImageSeries] [CT] (this media).

Processing Details

Creator
Date processed
2021-05-07
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000362754: Head [CTImageSeries] [CT] (this media)