Media 000362896: Braincase [Mesh] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000362896
Media type
Mesh
File format(s)
application/ply
File size
133,637,368 bytes
Object element or part
braincase
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Groenke, Joseph
Date created
--
Date uploaded
May 10, 2021
Points
1,672,864
Polygons
3,367,286
Map type
Normal
UV coordinates
False
Vertex color
False
Bounding box dimensions
170.278, 162.864, 239.969
Centroid coordinates
-2.308, 10.351, 1.715
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EAR_1123642; Ohio University Heritage College of Osteopathic Medicine; EAR_1525915
Publisher
Mahajanga Basin Project; Patrick M. O'Connor; Ohio University; Joseph R. Groenke
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:pr:2100 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Date
2009-01-20
Software
GE
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
250
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
541
Source detector distance
949.1
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Spiral

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000362893: Braincase [CTImageSeries] [CT] .

Processing Details

Creator
Groenke, Joseph
Date processed
2021-02-24
Software
Avizo
Description
Export stacks as DICOM data for zipping on MorphoSource
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000362893: Braincase [CTImageSeries] [CT] was processed to create derived Media 000362896: Braincase [Mesh] [CT] (this media).

Processing Details

Creator
Groenke, Joseph
Date processed
2021-02-24
Software
Avizo
Description
polygon output of isosurface
Description attachment
None

Media produced by this event on MorphoSource


Media 000362896: Braincase [Mesh] [CT] (this media)