Media 000363053: Anterior Body [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000363053
Media type
CTImageSeries
File format(s)
image/tiff
File size
2,734,196,073 bytes
Object element or part
anterior body
Side
--
Orientation
--
Short description
HRXCT scan - anterior body
Full description
University of Texas High-Resolution X-ray CT Facility Archive 1541 Cannatella: rhyacotriton: Scans of the head and shoulders of a whole preserved Rhyacotriton variegates (MVZ 98409) for David Cannatella of The University of Texas at Austin, Biology Department. Specimen scanned by Matthew Colbert 27 November 2006. Images flipped. 16bitrot: 1024x1024 16-bit TIFF images. II, 180 kV, 0.13 mA, no filter, empty container wedge, no offset, slice thickness 2 lines (= 0.02717 mm), S.O.D. 39 mm, 1400 views, 4 samples per view, inter-slice spacing 2 lines (= 0.02717 mm), field of reconstruction 12.5 mm (maximum field of view 12.92 mm), reconstruction offset 6500, reconstruction scale 4600. Acquired with 19 slices per rotation and 15 slices per set. Flash and ring-removal processing done by Alison Mote based on correction of raw sinogram data using IDL routines “RK_SinoDeSpike” and “RK_SinoRingProcSimul,” both with default parameters. Last four duplicate slices of each set deleted. Rotation correction processing done by Alison Mote based on IDL routine “DoRotationCorrection.” Total final slices = 990.
Creator
--
Date created
November 27, 2006
Date uploaded
May 10, 2021
Image width
918
Image height
804
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.01221
Y pixel spacing
0.01221
Z pixel spacing
0.02717
Pixel spacing units
Mm
Number of images in set
990

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Museum of Vertebrate Zoology
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
EF-0334952, DBI-1902242
Publisher
oUTCT PEN
Cite as
David Cannatella provided access to these data, with data collection funded by NSF EF-0334952 and data upload to MorphoSource funded by DBI-1902242.
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object mvz:amphibian and reptile specimens:98409 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Varian Medical Systems (Bio-Imaging Research, Inc) ACTIS CT scanner with FeinFocus X-ray source
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
2006-11-27
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
4
Projections
1400
Voltage
180
Power
--
Amperage
130
Surrounding material
empty container
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000363053: Anterior Body [CTImageSeries] [CT] (this media).

Processing Details

Creator
Date processed
2021-05-10
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000363053: Anterior Body [CTImageSeries] [CT] (this media)