Media 000363487: Femur [Mesh] [CT]
Represents:
Biological Specimen
In Collection

2 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000363487
Media type
Mesh
File format(s)
application/ply
File size
17,866,986 bytes
Object element or part
Femur
Side
Left
Orientation
--
Short description
Right mirrored
Full description
--
Creator
--
Date created
--
Date uploaded
May 13, 2021
Points
250,025
Polygons
500,046
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
10.859, 9.328, 58.03
Centroid coordinates
5.832, 4.139, -27.694
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object amnh:mammals:m-133688 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Justin Gladman
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.354
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
--
Frame averaging
2
Projections
2500
Voltage
172
Power
--
Amperage
85
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000085070: Femur, Fibula, Humerus, Radius, Tibia, Ulna [CTImageSeries] [Etc] .

Processing Details

Creator
Justin Gladman
Date processed
--
Software
--
Description
--
Description attachment
None

STEP 3: IMAGE PROCESSING

Derived Media 000085070: Femur, Fibula, Humerus, Radius, Tibia, Ulna [CTImageSeries] [Etc] was processed to create derived Media 000363487: Femur [Mesh] [CT] (this media).

Processing Details

Creator
Botton-Divet, Leo
Date processed
2021-05-13
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000363487: Femur [Mesh] [CT] (this media)