Media 000363579: Lacrimal [Mesh] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

GENERAL DETAILS

Media ID
000363579
Media type
Mesh
Object element or part
lacrimal
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 13, 2021

FILE OBJECT DETAILS

File origin
Local
File format(s)
application/ply
File size
44.4 MB
Points
613,880
Polygons
1,228,525
Map type
Normal
UV coordinates
False
Vertex color
False
Bounding box dimensions
146.057, 42.156, 194.392
Centroid coordinates
-8.516, 7.372, -10.753
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1123642; NSF EAR_1525915
Publisher
Joseph R. Groenke; Ohio University; Patrick M. O'Connor; Mahajanga Basin Project
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:pr:2100 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Date
January 13, 2009
Software
GE
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
250
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
541
Source detector distance
949.1
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Spiral

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000363576: Lacrimal [CTImageSeries] [CT] .

Processing Details

Creator
Groenke, Joseph
Date processed
May 13, 2021
Software
Avizo
Description
cropping of batch scans and export as dicoms
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000363576: Lacrimal [CTImageSeries] [CT] was processed to create derived Media 000363579: Lacrimal [Mesh] [CT] (this media).

Processing Details

Creator
Acker, Alex
Date processed
February 04, 2020
Software
Avizo
Description
export of ply format from isosurface rendering
Description attachment
None

Media produced by this event on MorphoSource


Media 000363579: Lacrimal [Mesh] [CT] (this media)