Media 000363778: Postorbital [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000363778
Media type
CTImageSeries
Object element or part
postorbital
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 17, 2021
FILE OBJECT DETAILS
File format(s)
application/dicom
File size
157 MB
Image width
512
Image height
512
Color space
--
Color depth
16
Compression
--
X pixel spacing
0.300781
Y pixel spacing
0.300781
Z pixel spacing
0.200000
Pixel spacing units
Mm
Slice thickness
0.625000
Number of images in set
820
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
NSF EAR_1123642; Ohio University Heritage College of Osteopathic Medicine; NSF EAR_1525915
Publisher
Ohio University; Joseph R. Groenke; Mahajanga Basin Project; Patrick M. O'Connor
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
fmnh:pr:2100
was imaged to create
undeposited raw media.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Date
March 06, 2012
Software
GE
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
140
Power
--
Amperage
250
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
541
Source detector distance
949.1
Target material
--
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Spiral
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000363778: Postorbital [CTImageSeries] [CT]
(this media).
Processing Details
Creator
Groenke, Joseph
Date processed
February 25, 2021
Software
Avizo
Description
cropping from batch scans and export as dicoms
Description attachment
None
Media produced by this event on MorphoSource
Media 000363778: Postorbital [CTImageSeries] [CT] (this media)