Media 000363928: Surangular And Articular [Mesh] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000363928
Media type
Mesh
File format(s)
application/ply
File size
102,207,636 bytes
Object element or part
surangular and articular
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 17, 2021
Points
1,318,095
Polygons
2,635,567
Map type
Normal
UV coordinates
False
Vertex color
False
Bounding box dimensions
73.225, 67.443, 317.624
Centroid coordinates
19.767, 1.217, 46.273
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT, Stony Brook University Medical Center (Stony Brook University)

OWNERSHIP AND PERMISSIONS

Data managed by
Download permission
Publish with Restricted Download
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
IP holder(s) (Name, Type)
--
Funding attribution
NSF EAR_1123642; NSF EAR_1525915; Ohio University Heritage College of Osteopathic Medicine
Publisher
Ohio University; Joseph R. Groenke; Mahajanga Basin Project; Patrick M. O'Connor
Cite as
--
Additial usage agreement
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:pr:2100 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric LightSpeed VCT 64-slice CT
Device facility
Stony Brook University Medical Center (Stony Brook University)
Creator
Groenke, Joseph
Date
2012-03-05
Software
GE
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
1825
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
--
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
541
Source detector distance
949.1
Target material
--
Rotation number
--
Phase contrast
Yes
Optical magnification
Yes
Acquisition type
Spiral

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000363925: Surangular And Articular [CTImageSeries] [CT] .

Processing Details

Creator
Groenke, Joseph
Date processed
2021-02-26
Software
Avizo
Description
crop from batch scans and export as dicoms
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000363925: Surangular And Articular [CTImageSeries] [CT] was processed to create derived Media 000363928: Surangular And Articular [Mesh] [CT] (this media).

Processing Details

Creator
Acker, Alex
Date processed
2020-01-28
Software
Avizo
Description
export ply format from isosurface rendering
Description attachment
None

Media produced by this event on MorphoSource


Media 000363928: Surangular And Articular [Mesh] [CT] (this media)