Media 000364002: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000364002
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Phyllomedusa bicolor
Object organization
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 18, 2021

FILE OBJECT DETAILS Field Definitions

File name
Phyllomedusa_bicolor_CAS257760.zip
File format(s)
ZIP archive, TIFF
File size
424 MB
Image width
1371
Image height
562
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.083797
Y pixel spacing
0.083797
Z pixel spacing
0.083797
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,839

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
California Academy of Sciences
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF DBI-1701714
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object CAS:HERP:257760 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
May 20, 2021
Software
Datos|X A
Description
MicroCT cas:herp:259760
Description attachment
None
Reference attachment
None
Exposure time
0.200089
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1700
Voltage
120KV
Power
18W
Amperage
150uA
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000364002: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
May 17, 2021
Software
Datos|X R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000364002: Whole Body [CTImageSeries] [CT] (this media)