Media 000364032: Bone Fragment 2
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000364032
Media type
Mesh
Object element or part
Bone fragment 2
Object represented
Object taxonomy
Marmoretta oxoniensis
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 18, 2021

FILE OBJECT DETAILS Field Definitions

File name
Bone_2.ply
File format(s)
PLY
File size
25.8 KB
Points
598
Polygons
1184
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
354.963, 423.384, 321.061
Centroid coordinates
10200.420, 3254.421, 1582.562
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
Elizabeth Griffiths
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object camsm:X9991 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
School of Earth Sciences Xray Tomography (XTM) Facility (University of Bristol)
Creator
--
Event date
May 19, 2021
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5 seconds
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
3141
Voltage
175
Power
--
Amperage
103
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
0.0104383
Detector pixels Y
--
Detector pixels size Y
0.0104383
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000363889: Posterior Lower Jaw [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
May 17, 2021
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000363889: Posterior Lower Jaw [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000364032: Bone Fragment 2 [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Elizabeth Griffiths
Event date
May 18, 2021
Software
Mimics Research
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Mimics Research
Description

Media produced by this event on MorphoSource

Media 000364032: Bone Fragment 2 [Mesh] [CT] (this media)