Media 000364556: Whole Body
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen

Media Display

In Collections

Project
· Public
Team
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000364556
Media type
Volumetric Image Series
Object element or part
whole body
Object represented
Object taxonomy
Elachistocleis bicolor
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
May 20, 2021

FILE OBJECT DETAILS Field Definitions

File name
Elachistocleis_bicolor_AMNH19891.zip
File format(s)
ZIP archive, TIFF
File size
1.12 GB
Image width
459
Image height
838
Color space
BlackIsZero
Color depth
16
Compression
PackBits
Series type
Reconstructed image stack
X pixel spacing
0.024214
Y pixel spacing
0.024214
Z pixel spacing
0.024214
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
2,021

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS Field Definitions

Data uploaded by
Publication status
Restricted Download
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
oVert TCN; NSF DBI-1701714
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object AMNH:Herpetology:A-19891 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Event date
May 26, 2021
Software
Datos|X A
Description
MicroCT of AMNH-a-19891
Description attachment
None
Reference attachment
None
Exposure time
0.200089
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
3
Projections
1600
Voltage
70KV
Power
21W
Amperage
300uA
Surrounding material
air
X-ray tube type
--
Target type
Reflection
Detector type
Scintillator (Phosphor used)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
Tungston (W)
Rotation number
--
Phase contrast
No
Optical magnification
No
Acquisition type
Sequenced

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000364556: Whole Body [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Edward Stanley
Event date
May 20, 2021
Software
Datos|X R
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000364556: Whole Body [CTImageSeries] [CT] (this media)