Media 000367163: Fruit
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000367163: Fruit
Open Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
No collections found.
TAGS
GENERAL DETAILS Field Definitions
Media ID
000367163
Media type
Mesh
Object element or part
Fruit
Object represented
Object taxonomy
Hippomane spinosa
Object organization
Side
--
Orientation
--
Short description
Extracted Surface of fruit
Full description
--
Creator
Steven R. Manchester
Date created
January 15, 2021
Date uploaded
June 08, 2021
FILE OBJECT DETAILS Field Definitions
File name
ExtractedSurfaceendocarp.ply
File format(s)
PLY
File size
57.7 MB
Points
1575121
Polygons
3183038
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
402.954, 416.821, 421.681
Centroid coordinates
255.133, 256.230, 271.497
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
US:US:US 2114065
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Steven R. Manchester
Event date
--
Software
--
Description
Extracted surface
Description attachment
None
Reference attachment
None
Exposure time
131.099
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1900
Voltage
60
Power
--
Amperage
500
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000367163: Fruit [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Steven R. Manchester
Event date
June 08, 2021
Software
--
Description
Extracted surface
Description attachment
None
Media produced by this event on MorphoSource
Media 000367163: Fruit [Mesh] [CT] (this media)