Media 000368735: Navicular [Mesh] [CT]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000368735
Media type
Mesh
File format(s)
application/ply
File size
11,108,528 bytes
Object element or part
navicular
Side
Left
Orientation
--
Short description
left navicular from articulated foot
Full description
--
Creator
doug boyer
Date created
June 21, 2021
Date uploaded
June 22, 2021
Points
153,623
Polygons
307,242
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
8.792, 8.156, 4.723
Centroid coordinates
6.544, 10.439, 9.872
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
Duke Lemur Center
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
NSF BCS-1552848
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object dlc:360m was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Gabriel Yapuncich, Darbi Griffith
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
No
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
1
Projections
2000
Voltage
140
Power
0.029
Amperage
205
Surrounding material
Air
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000015175: Foot [CTImageSeries] [Etc] .

Processing Details

Creator
Gabriel Yapuncich, Darbi Griffith
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000015175: Foot [CTImageSeries] [Etc] was processed with 1 activity to create derived Media 000368735: Navicular [Mesh] [CT] (this media).

Processing Details

Creator
doug boyer
Date processed
2021-06-21
Software
Avizo
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description

Media produced by this event on MorphoSource


Media 000368735: Navicular [Mesh] [CT] (this media)