Media 000370643: Hand [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000370643
Media type
CTImageSeries
File format(s)
image/tiff
File size
1,491,824,407 bytes
Object element or part
Hand
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Yapuncich, Gabriel
Date created
September 06, 2020
Date uploaded
July 20, 2021
Image width
1875
Image height
1148
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
Series type
Reconstructed image stack
X pixel spacing
0.104183
Y pixel spacing
0.104183
Z pixel spacing
0.104183
Pixel spacing units
Mm
Number of images in set
2,000

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Share Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
Boyer, Doug (Copyright and License)
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:HC628 was imaged to create this media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Share Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Yapuncich, Gabriel
Date
2020-09-06
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.354
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Filter
--
Frame averaging
--
Projections
1800
Voltage
180
Power
--
Amperage
190
Surrounding material
air
Xray tube type
--
Target type
Transmission
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

Media produced by this event on MorphoSource


Media 000370643: Hand [CTImageSeries] [CT] (this media)