Media 000370652: Hand [Mesh] [CT]
Represents:
Biological Specimen
In Collection
Login or create an account to download files
1 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT
COLLECTIONS MEDIA BELONGS TO
MEDIA TAGS
GENERAL DETAILS
Media ID
000370652
Media type
Mesh
Object element or part
Hand
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Gabriel Yapuncich
Date created
September 11, 2020
Date uploaded
July 20, 2021
FILE OBJECT DETAILS
File format(s)
application/ply
File size
19.9 MB
Points
549,854
Polygons
1,099,740
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
115.625, 26.744, 183.502
Centroid coordinates
100.745, 53.061, 120.069
Units of point coordinates
Mm
IMAGE ACQUISITION AND PROCESSING AT A GLANCE
Number of parent media
1
Number of processing events
1
(1 step)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
OWNERSHIP AND PERMISSIONS
Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
du:ea:HC628
was imaged to create
raw media
Media 000370643: Hand [CTImageSeries] [CT]
.
Imaging Details
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Yapuncich, Gabriel
Date
September 06, 2020
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Filter
--
Exposure time
0.354
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
--
Projections
1800
Voltage
180
Power
--
Amperage
190
Surrounding material
air
Xray tube type
--
Target type
Transmission
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced
Media produced by this event on MorphoSource
STEP 2: IMAGE PROCESSING
Raw
Media 000370643: Hand [CTImageSeries] [CT]
was processed
with 1 activity
to create
derived
Media 000370652: Hand [Mesh] [CT]
(this media).
Processing Details
Creator
Gabriel Yapuncich
Date processed
September 11, 2020
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstructed Tomography to Mesh
Software
Avizo
Description
Media produced by this event on MorphoSource
Media 000370652: Hand [Mesh] [CT] (this media)