Media 000370652: Hand
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

Project
· Public

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000370652
Media type
Mesh
Object element or part
Hand
Object represented
Object taxonomy
Homo sapiens
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Gabriel Yapuncich
Date created
September 11, 2020
Date uploaded
July 20, 2021

FILE OBJECT DETAILS Field Definitions

File name
DU_EA628_Homo_sapiens_R_hand.ply
File format(s)
PLY
File size
19.9 MB
Points
549854
Polygons
1099740
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
115.625, 26.744, 183.502
Centroid coordinates
100.745, 53.061, 120.069
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object du:ea:HC628 was imaged to create raw Media 000370643: Hand [CTImageSeries] [CT].

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Yapuncich, Gabriel
Event date
September 06, 2020
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.354
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
--
Projections
1800
Voltage
180
Power
--
Amperage
190
Surrounding material
air
X-ray tube type
--
Target type
Transmission
Detector type
Direct (X-Ray photoconductor)
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
Area (single or tiled detector)
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
Sequenced

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000370643: Hand [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000370652: Hand [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Gabriel Yapuncich
Event date
September 11, 2020
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description

Media produced by this event on MorphoSource

Media 000370652: Hand [Mesh] [CT] (this media)