Media 000371696: Venom Delivery System
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000371696
Media type
Mesh
Object element or part
Venom Delivery System
Object represented
Object taxonomy
Pseudonaja textilis
Side
Left
Orientation
--
Short description
venom delivery system of Pseudonaja textilis
Full description
Extraxted venom delivery system based on DicecT stained head of Pseudonaja textilis
Creator
Cleuren, Silke
Date created
March 13, 2020
Date uploaded
July 24, 2021

FILE OBJECT DETAILS Field Definitions

File name
Pseu-text_NMVD77144_DiceCT_Left_All.ply
File format(s)
PLY
File size
35.2 MB
Points
490422
Polygons
983444
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
5748.230, 4757.228, 9430.290
Centroid coordinates
10083.992, 2511.281, 9679.817
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm), Evans EvoMorph Laboratory (Monash University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
Australian Research Council; Holsworth Research Endowment; Monash University
Publisher
Monash University; Museums Victoria
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object nmv:herpetology:D77144 was imaged to create raw Media 000371650: Head [CTImageSeries] [CT].

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm)
Device facility
Evans EvoMorph Laboratory (Monash University)
Creator
Cleuren, Silke
Event date
February 20, 2020
Software
ZEISS XRadia Versa
Description
DiceCT Head Pseudonaja textilis
Description attachment
None
Reference attachment
None
Exposure time
3 s
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
1601
Voltage
80 kV
Power
7 W
Amperage
88 uA
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
Yes
Acquisition type
--

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000371650: Head [CTImageSeries] [CT] was processed with 1 activity to create derived Media 000371696: Venom Delivery System [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Cleuren, Silke
Event date
March 13, 2020
Software
Avizo
Description
Extracted venom delivery system
Description attachment
None

Processing Activity 1: Reconstructed Tomography to Mesh

Software
Avizo
Description
Segmented out VDS

Media produced by this event on MorphoSource

Media 000371696: Venom Delivery System [Mesh] [CT] (this media)