Media 000373481: Cranium
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000373481
Media type
Mesh
Object element or part
Cranium
Object taxonomy
Gopherus agassizii
Side
NotApplicable
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
August 02, 2021
Date uploaded
August 02, 2021

FILE OBJECT DETAILS Field Definitions

File name
Gopherus_agassizii_FMNH_216746_Cranium.ply
File format(s)
PLY
File size
232 MB
Points
5536972
Polygons
11039864
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
38.027, 53.330, 25.847
Centroid coordinates
19.857, 30.807, 21.585
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:amphibians and reptiles:216746 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Isch Neander
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
2
Projections
1800
Voltage
80
Power
--
Amperage
200
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000077406: Element Unspecified [CTImageSeries] [Etc].

Processing Details Field Definitions

Creator
April Isch Neander
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000077406: Element Unspecified [CTImageSeries] [Etc] was processed to create derived Media 000373481: Cranium [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Serjoscha Evers
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000373481: Cranium [Mesh] [CT] (this media)