Media 000373728: Endosseous Labyrinth [Mesh] [CT]
Represents:
Biological Specimen
In Collection

FILE OBJECT DETAILS

Media ID
000373728
Media type
Mesh
File format(s)
application/ply
File size
1,194,143 bytes
Object element or part
Endosseous labyrinth
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
August 02, 2021
Date uploaded
August 02, 2021
Points
27,130
Polygons
54,268
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
10731.959, 16153.602, 15659.783
Centroid coordinates
35699.228, 82897.156, 35729.706
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x S240, Laboratory for Virtual Anthropology and Morphometrics (University of Tübingen)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
IP holder
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:pr:273 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x S240
Device facility
Laboratory for Virtual Anthropology and Morphometrics (University of Tübingen)
Creator
Scherf, Heike
Date
2012-03-08
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
333 ms
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Filter
--
Frame averaging
--
Projections
--
Voltage
150 kV
Power
--
Amperage
170 uA
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000355953: Cranium [CTImageSeries] [CT] .

Processing Details

Creator
Scherf, Heike
Date processed
2012-03-08
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000355953: Cranium [CTImageSeries] [CT] was processed to create derived Media 000373728: Endosseous Labyrinth [Mesh] [CT] (this media).

Processing Details

Creator
Serjoscha Evers
Date processed
--
Software
Mimics
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000373728: Endosseous Labyrinth [Mesh] [CT] (this media)