Media 000374106: Endosseous Labyrinth
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS

Media ID
000374106
Media type
Mesh
Object element or part
Endosseous labyrinth
Object taxonomy
Sternotherus minor
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Serjoscha Evers
Date created
August 03, 2021
Date uploaded
August 03, 2021

FILE OBJECT DETAILS

File format(s)
application/ply
File size
1.74 MB
Points
41440
Polygons
82638
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
15.757, 16.885, 14.701
Centroid coordinates
18.578, 27.864, 41.109
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object FMNH:Amphibians and Reptiles:211696 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
April Isch Neander
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
--
Projections
--
Voltage
80
Power
--
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000042852: Tiff Stack [CTImageSeries] [Etc].

Processing Details

Creator
April Isch Neander
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000042852: Tiff Stack [CTImageSeries] [Etc] was processed to create derived Media 000374106: Endosseous Labyrinth [Mesh] [CT] (this media).

Processing Details

Creator
Serjoscha Evers
Date processed
--
Software
Mimics
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000374106: Endosseous Labyrinth [Mesh] [CT] (this media)