Media 000375284: Skull
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000375284: Skull
Restricted Download
Type
Mesh
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
Media Display
In Collections
Team
· Public
TAGS
GENERAL DETAILS Field Definitions
Media ID
000375284
Media type
Mesh
Object element or part
Skull
Object represented
Object taxonomy
Euryceros prevostii
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Sergio M. Nebreda
Date created
August 05, 2021
Date uploaded
August 05, 2021
FILE OBJECT DETAILS Field Definitions
File name
Euryceros-prevostii_FMNH_B_356692_red.ply
File format(s)
PLY
File size
4.48 MB
Points
113461
Polygons
248359
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
30.538, 57.771, 38.306
Centroid coordinates
21.046, 36.118, 73.204
Units of point coordinates
--
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
1
Number of processing events
2
(0 steps)
Derived directly from
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
FMNH:Birds:356692
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
Stephanie Baumgart, Daryl Coldren, April Neander
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0.25
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Frame averaging
3
Projections
1100
Voltage
170
Power
0.0595
Amperage
350
Surrounding material
Air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
to create
derived
Media 000078335: Element Unspecified [CTImageSeries] [Etc].
Processing Details Field Definitions
Creator
Stephanie Baumgart, Daryl Coldren, April Neander
Event date
--
Software
--
Description
--
Description attachment
None
Media produced by this event on MorphoSource
STEP 3: IMAGE PROCESSING
Derived
Media 000078335: Element Unspecified [CTImageSeries] [Etc]
was processed
to create
derived
Media 000375284: Skull [Mesh] [CT] (this media).
Processing Details Field Definitions
Creator
Sergio M. Nebreda
Event date
August 05, 2021
Software
Avizo
Description
--
Description attachment
None
Media produced by this event on MorphoSource
Media 000375284: Skull [Mesh] [CT] (this media)