Media 000375873: Sternum
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000375873
Media type
Mesh
Object element or part
Sternum
Object represented
Object taxonomy
Cariama cristata
Object organization
Side
--
Orientation
--
Short description
--
Full description
--
Creator
Benson, Roger
Date created
August 06, 2021
Date uploaded
August 06, 2021

FILE OBJECT DETAILS Field Definitions

File name
Cariama_cristata_UMZC_724_sternum.ply
File format(s)
PLY
File size
31.1 MB
Points
429885
Polygons
870771
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
76.336, 65.056, 122.762
Centroid coordinates
129.594, 37.887, 114.854
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
UMZC Zoological Specimens
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson
Publisher
--
Cite as
Roger Benson provided access to these data, originally appearing in Lowi-Merri et al (2021) BMC Biology "The relationship between sternum variation and mode of locomotion in birds", the collection of which was funded by the European Research Council (ERC) starting grant TEMPO (ERC-2015-STG-677774) to Roger Benson. The files were downloaded from www.MorphoSource.org, Duke University
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UMZC:Vertebrates:724 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
Benson, Roger
Event date
--
Software
CT Pro 3D
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
1
Projections
--
Voltage
--
Power
--
Amperage
--
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000375527: Skeleton [CTImageSeries] [CT].

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000375527: Skeleton [CTImageSeries] [CT] was processed to create derived Media 000375873: Sternum [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Benson, Roger
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000375873: Sternum [Mesh] [CT] (this media)