Media 000379250: Frontal
Open Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS

Media ID
000379250
Media type
Mesh
Object element or part
Frontal
Object represented
Object taxonomy
Lakotemys australodakotensis
Side
Left
Orientation
--
Short description
--
Full description
--
Creator
Yann Rollot
Date created
August 23, 2021
Date uploaded
August 23, 2021

FILE OBJECT DETAILS

File format(s)
application/ply
File size
1.68 MB
Points
25981
Polygons
51958
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
6863.398, 4933.898, 18805.330
Centroid coordinates
32781.178, 24801.966, 12283.002
Units of point coordinates
--

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
1
Number of processing events
2 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build, The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Publication status
Open Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object omnh:vp:66106 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
North Star Imaging NSI Custom build
Device facility
The University of Texas High-Resolution X-ray Computed Tomography Facility (University of Texas at Austin)
Creator
Matthew Colbert
Date
December 16, 2009
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
--
Voltage
210 kV
Power
--
Amperage
0.17 mA
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000379247: Cranium [CTImageSeries] [CT].

Processing Details

Creator
--
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

STEP 3: IMAGE PROCESSING

Derived Media 000379247: Cranium [CTImageSeries] [CT] was processed to create derived Media 000379250: Frontal [Mesh] [CT] (this media).

Processing Details

Creator
Yann Rollot
Date processed
--
Software
Amira
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000379250: Frontal [Mesh] [CT] (this media)