Media 000381496: Calcaneus
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Media 000381496: Calcaneus
Restricted Download
Type
Volumetric Image Series
Modality
X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by
Login or create an account to download files
GENERAL DETAILS Field Definitions
Media ID
000381496
Media type
Volumetric Image Series
Object element or part
Calcaneus
Object represented
Object taxonomy
Euoticus elegantulus
Object organization
Side
Right
Orientation
--
Short description
--
Full description
--
Creator
Kristi Lewton
Date created
March 18, 2019
Date uploaded
September 01, 2021
FILE OBJECT DETAILS Field Definitions
File name
Euoticus_elegantulus_PCM_842_res018_R_cal_reoriented_forMorphosource.zip
File format(s)
ZIP archive, DICOM
File size
161 MB
Image width
343
Image height
361
Color space
--
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.018371
Y pixel spacing
0.018371
Z pixel spacing
0.018371
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,323
IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions
Number of parent media
0
Number of processing events
1
(2 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)
OWNERSHIP AND PERMISSIONS Field Definitions
Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
National Science Foundation BCS 1944571; Office of the Provost of the University of Southern California
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None
IDENTIFIERS AND EXTERNAL LINKS Field Definitions
MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--
IMAGE ACQUISITION AND PROCESSING IN DETAIL
STEP 1: IMAGE ACQUISITION
Physical object
p-cm:NH.MER34.842
was imaged to create
undeposited raw media.
IMAGING DETAILS Field Definitions
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
--
Event date
March 18, 2019
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
3142
Voltage
145
Power
--
Amperage
170
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--
STEP 2: IMAGE PROCESSING
Raw media (undeposited)
was processed
with 2 activities
to create
derived
Media 000381496: Calcaneus [CTImageSeries] [CT] (this media).
Processing Details Field Definitions
Creator
Kristi Lewton
Event date
--
Software
--
Description
--
Description attachment
None
Processing Activity 1: Reconstruction
Software
Description
Processing Activity 2: Transform: Rotation
Software
Avizo
Description
Media produced by this event on MorphoSource
Media 000381496: Calcaneus [CTImageSeries] [CT] (this media)