Media 000381810: Calcaneus
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000381810
Media type
Volumetric Image Series
Object element or part
Calcaneus
Object represented
Object taxonomy
Galagoides demidoff
Object organization
Side
Left
Orientation
--
Short description
--
Full description
These image data have been mirror-imaged to reflect a right-side specimen
Creator
Kristi Lewton
Date created
March 19, 2019
Date uploaded
September 04, 2021

FILE OBJECT DETAILS Field Definitions

File name
Galagoides_demidovii_PCM_NH-MER-33-437_L_res012_mirrored_calc_reoriented_revised_forMorphosource.zip
File format(s)
ZIP archive, DICOM
File size
293 MB
Image width
541
Image height
587
Color space
--
Color depth
16
Compression
--
Series type
Reconstructed image stack
X pixel spacing
0.011657
Y pixel spacing
0.011657
Z pixel spacing
0.011657
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
1,869

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (3 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Cambridge Biotomography Centre (University of Cambridge)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
National Science Foundation BCS 1944571; Office of the Provost of the University of Southern California
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object p-cm:NH.MER33.437 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Cambridge Biotomography Centre (University of Cambridge)
Creator
--
Event date
March 19, 2019
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
3142
Voltage
135
Power
--
Amperage
170
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 3 activities to create derived Media 000381810: Calcaneus [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
Kristi Lewton
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Processing Activity 2: Transform: Reflection

Software
Avizo
Description

Processing Activity 3: Transform: Rotation

Software
Avizo
Description

Media produced by this event on MorphoSource

Media 000381810: Calcaneus [CTImageSeries] [CT] (this media)