Media 000381897: Metacarpal Fragment
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000381897
Media type
Volumetric Image Series
Object element or part
Metacarpal Fragment
Object represented
Object taxonomy
Nannodectes intermedius
Side
Unknown
Orientation
--
Short description
Correct chirality. nn5
Full description
--
Creator
--
Date created
--
Date uploaded
September 06, 2021

FILE OBJECT DETAILS Field Definitions

File name
ProxPhalA_pal442229.zip
File format(s)
ZIP archive, TIFF
File size
109 MB
Image width
300
Image height
499
Color space
BlackIsZero
Color depth
16
Compression
LZW
X pixel spacing
0.008801
Y pixel spacing
0.008801
Z pixel spacing
0.008801
Pixel spacing units
Mm
Slice thickness
--
Number of images in set
363

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
1 (1 step)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
Smithsonian, National Museum of Natural History
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object USNM:PAL:USNM PAL442229 was imaged to create undeposited raw media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
--
Projections
2000
Voltage
115
Power
13,445
Amperage
117
Surrounding material
air
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
2000
Detector pixels size X
0.2
Detector pixels Y
2000
Detector pixels size Y
0.2
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed with 1 activity to create derived Media 000381897: Metacarpal Fragment [CTImageSeries] [CT] (this media).

Processing Details Field Definitions

Creator
--
Event date
--
Software
--
Description
--
Description attachment
None

Processing Activity 1: Reconstruction

Software
Description

Media produced by this event on MorphoSource

Media 000381897: Metacarpal Fragment [CTImageSeries] [CT] (this media)