Media 000383673: Intermediate Phalanx A
Restricted Download
Type Mesh
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

In Collections

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000383673
Media type
Mesh
Object element or part
intermediate phalanx A
Object represented
Object taxonomy
Nannodectes intermedius
Side
--
Orientation
--
Short description
Houde 142, associated with Media 000383652: Distal Phalanx A
Full description
--
Creator
Doug Boyer
Date created
September 17, 2021
Date uploaded
September 17, 2021

FILE OBJECT DETAILS Field Definitions

File name
Boyer_USNM_pal442229_int_phal_a-.smooth.ply
File format(s)
PLY
File size
22.3 MB
Points
311144
Polygons
622272
Map type
--
UV coordinates
False
Vertex color
False
Bounding box dimensions
2.523, 3.249, 6.556
Centroid coordinates
1.483, 1.880, 3.817
Units of point coordinates
Mm

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
1
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST, Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
Download reviewer
IP holder
--
Copyright statement
--
Creative Commons license
--
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Nikon Metrology XT H 225 ST
Device facility
Duke Shared Materials Instrumentation Facility (SMiF) (Duke University)
Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
--
Flux normalization
--
Pixel spacing calibration
--
Shading correction
Yes
Frame averaging
--
Projections
--
Voltage
115
Power
--
Amperage
117
Surrounding material
--
X-ray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

STEP 2: IMAGE PROCESSING

Raw Media 000383670: Intermediate Phalanx A [CTImageSeries] [CT] was processed to create derived Media 000383673: Intermediate Phalanx A [Mesh] [CT] (this media).

Processing Details Field Definitions

Creator
Doug Boyer
Event date
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource

Media 000383673: Intermediate Phalanx A [Mesh] [CT] (this media)