Media 000386514: Body [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000386514
Media type
CTImageSeries
File format(s)
image/tiff
File size
3,737,999,897 bytes
Object element or part
body
Side
NotApplicable
Orientation
--
Short description
microCT volume and derivatives
Full description
Migrated MorphoSource 1 Media File Title: zipped tiff stack Migrated MorphoSource 1 Media Group Title: microCT volume and derivatives Record created by batch submission.
Creator
--
Date created
--
Date uploaded
September 28, 2021
Image width
1889
Image height
574
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.0282782
Y pixel spacing
0.0282782
Z pixel spacing
0.0282782
Pixel spacing units
Mm
Number of images in set
2,022

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240, UF Nanoscale Research Facility (University of Florida)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Open Download
Download reviewer
IP holder
Florida Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oVert TCN; NSF DBI-1701714
Publisher
--
Cite as
Migrated MorphoSource 1 Media Citation Instructions: University of Florida provided access to these data provided access to these data , the collection of which was funded by oVert TCN; NSF DBI-1701714.. The files were downloaded from www.MorphoSource.org, Duke University.
Media preview mode
Interactive/Embeddable
Additional usage agreement

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UF:Herp:59713 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x m 240
Device facility
UF Nanoscale Research Facility (University of Florida)
Creator
Edward Stanley
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.333
Flux normalization
Yes
Pixel spacing calibration
--
Shading correction
Yes
Filter
0.1 mm Cu
Frame averaging
3
Projections
2200
Voltage
100
Power
0.02
Amperage
200
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000386514: Body [CTImageSeries] [CT] (this media).

Processing Details

Creator
Edward Stanley
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000386514: Body [CTImageSeries] [CT] (this media)