Media 000386929: Whole Body [CTImageSeries] [CT]
Represents:
Biological Specimen
In Collection

0 ADDITIONAL MEDIA RELATED TO ACQUISITION EVENT

COLLECTIONS MEDIA BELONGS TO

MEDIA TAGS

FILE OBJECT DETAILS

Media ID
000386929
Media type
CTImageSeries
File format(s)
image/tiff
File size
244,044,732 bytes
Object element or part
whole body
Side
NotApplicable
Orientation
--
Short description
microCT volume, zipped 16-bit tiff stack
Full description
Migrated MorphoSource 1 Media Group Title: microCT volume, zipped 16-bit tiff stack Migrated MorphoSource 1 Media Group Description: Data inverted following reconstruction Record created by batch submission.
Creator
--
Date created
--
Date uploaded
September 28, 2021
Image width
535
Image height
420
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
56.7177
Y pixel spacing
56.7177
Z pixel spacing
56.7177
Pixel spacing units
Mm
Number of images in set
807

IMAGE ACQUISITION AND PROCESSING AT A GLANCE

Number of parent media
0
Number of processing events
1 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm), Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)

OWNERSHIP AND PERMISSIONS

Data managed by
Data uploaded by
Download permission
Publish with Restricted Download
Download reviewer
IP holder
University of Colorado Museum of Natural History
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On MorphoSource
Funding attribution
oMeso PEN NSF DBI-2001474; oVert TCN partner NSF DBI-1701729
Publisher
University of Colorado Museum of Natural History
Cite as
UCM Herp [catalog number]
Media preview mode
Interactive/Embeddable
Additional usage agreement
None

IDENTIFIERS AND EXTERNAL LINKS

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object UCM:Amphibian and reptile specimens:UCM:Herp:15980 was imaged to create undeposited raw media.

Imaging Details

Modality
X-Ray Computed Tomography (CT/microCT)
Device
Zeiss Xradia 520 Versa x-ray microscope (xrm)
Device facility
Materials Instrumentation and Multimodal Imaging Core Facility (MIMIC) (University of Colorado, Boulder)
Creator
Green, Mariah
Date
--
Software
--
Description
--
Imaging event description attachment
None
Imaging event reference attachment
None
Exposure time
0.5
Flux normalization
No
Pixel spacing calibration
--
Shading correction
No
Filter
Air
Frame averaging
--
Projections
3201
Voltage
120
Power
0.01
Amperage
0.083
Surrounding material
--
Xray tube type
--
Target type
--
Detector type
--
Detector pixels X
--
Detector pixel size X
--
Detector pixels Y
--
Detector pixel size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

STEP 2: IMAGE PROCESSING

Raw media (undeposited) was processed to create derived Media 000386929: Whole Body [CTImageSeries] [CT] (this media).

Processing Details

Creator
Green, Mariah
Date processed
--
Software
--
Description
--
Description attachment
None

Media produced by this event on MorphoSource


Media 000386929: Whole Body [CTImageSeries] [CT] (this media)