Media 000387919: Skull
Restricted Download
Type Volumetric Image Series
Modality X-Ray Computed Tomography (CT/microCT)
Media represents biological specimen
Managed by

Media Display

TAGS

No tags found.

GENERAL DETAILS Field Definitions

Media ID
000387919
Media type
Volumetric Image Series
Object element or part
skull
Object represented
Object taxonomy
Varanodon agilis
Side
--
Orientation
--
Short description
--
Full description
--
Creator
--
Date created
--
Date uploaded
September 30, 2021

FILE OBJECT DETAILS Field Definitions

File name
RawData_-_varanodon.zip
File format(s)
ZIP archive, TIFF
File size
10.5 GB
Image width
1700
Image height
2024
Color space
BlackIsZero
Color depth
16
Compression
Uncompressed
X pixel spacing
0.095339 mm
Y pixel spacing
0.095339 mm
Z pixel spacing
0.095339 mm
Pixel spacing units
--
Slice thickness
--
Number of images in set
1,711

IMAGE ACQUISITION AND PROCESSING AT A GLANCE Field Definitions

Number of parent media
0
Number of processing events
0 (0 steps)
Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s, UChicago PaleoCT (University of Chicago)

OWNERSHIP AND PERMISSIONS Field Definitions

Data managed by
Data uploaded by
Publication status
Restricted Download
IP holder
--
Copyright statement
Morphosource use agreement type
Standard
Permits commercial use
Commercial Use Not Permitted
Permits 3D use
3D Printing Limited
Required archival of published derivatives
On Any Repository
Funding attribution
--
Publisher
--
Cite as
--
Media preview mode
Interactive/Embeddable

IDENTIFIERS AND EXTERNAL LINKS Field Definitions

MorphoSource ARK
MorphoSource DOI
Not assigned
External identifier
--
External media URL
--

IMAGE ACQUISITION AND PROCESSING IN DETAIL

STEP 1: IMAGE ACQUISITION

Physical object fmnh:FMNH UR 986 was imaged to create this media.

IMAGING DETAILS Field Definitions

Modality
X-Ray Computed Tomography (CT/microCT)
Device
General Electric phoenix v|tome|x s
Device facility
UChicago PaleoCT (University of Chicago)
Creator
--
Event date
--
Software
--
Description
--
Description attachment
None
Reference attachment
None
Exposure time
0h39m
Flux normalization
--
Pixel spacing calibration
--
Shading correction
--
Frame averaging
3
Projections
1700
Voltage
120kV
Power
--
Amperage
400uA
Surrounding material
--
X-ray tube type
240
Target type
--
Detector type
--
Detector pixels X
--
Detector pixels size X
--
Detector pixels Y
--
Detector pixels size Y
--
Detector configuration
--
Source object distance
--
Source detector distance
--
Target material
--
Rotation number
--
Phase contrast
--
Optical magnification
--
Acquisition type
--

Media produced by this event on MorphoSource

Media 000387919: Skull [CTImageSeries] [CT] (this media)